T16-10 Thermal Overload Relay

Product Code: 1SAZ711201R1043
Reviews: (0)
In Stock
0.00грн.
Ex Tax: 0.00грн.
Buy in one click
Specifications: (see all)
ABS Certificate
1SAA941001-0102
Ambient Air Temperature
Operation -25 ... +60 °C/Operation Compensated -25 ... +60 °C/Storage -50 ... +80 °C
Ambient Air Temperature Compensation
Yes
Ampere Rating UL/CSA
10 A
BV Certificate
1SAA941001-0203
The T16-10 thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10. Further features are the temperature compensation, trip contact (NC), signal contact (NO), automatic- or manual reset selectable, trip-free mechanism, STOP function and a trip indication. The overload relays are connected directly to the mini contactors or block contactors. Single mounting kits are available as accessory.
General characteristics
ABS Certificate
1SAA941001-0102
Ambient Air Temperature
Operation -25 ... +60 °C/Operation Compensated -25 ... +60 °C/Storage -50 ... +80 °C
Ambient Air Temperature Compensation
Yes
Ampere Rating UL/CSA
10 A
BV Certificate
1SAA941001-0203
CB Certificate
1SAA941008-2001
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²/Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²/Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²/Flexible 1/2x 0.75 ... 1 mm²/Flexible 1/2x 1 ... 2.5 mm²/Rigid 1/2x 0.75 ... 4 mm²
Connecting Capacity Auxiliary Circuit UL/CSA
Flexible 1/2x 18-12 AWG/Stranded 1/2x 18-12 AWG
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 0.75 ... 4 mm²/Flexible with Insulated Ferrule 1/2x 0.75 ... 4 mm²/Flexible 1/2x 0.75 ... 4 mm²/Solid 1/2x 0.75 ... 1.5 mm²/Solid 1/2x 1.5 ... 4 mm²/Stranded 1/2x 1 ... 4 mm²
Connecting Capacity Main Circuit UL/CSA
Flexible 1/2x 18-12 AWG/Stranded 1/2x 18-10 AWG
Contact Rating UL/CSA
(NC:) B600/(NC:) Q600/(NO:) Q600/(NO:) D300
Conventional Free-air Thermal Current (Ith)
Auxiliary Circuit NC 6 A/Auxiliary Circuit NO 4 A
CQC Certificate
CQC2011010309459316
cUL Certificate
cUL_E48139
Customs Tariff Number
85364900
Data Sheet, Technical Information
2CDC106020D0201
Declaration of Conformity - CCC
2020980304001787
Declaration of Conformity - CE
1SAD938510-0182
Degree of Protection
IP20
Dimension Diagram
1SAZ700404F0001
DNV GL Certificate
1SAA941001-0302
E-Number (Finland)
3706148
E-Number (Sweden)
3212069
EAC Certificate
1SAA941002-2702
eClass
V11.0 : 27371501
Environmental Information
1SAC200055H0009
ETIM 4
EC000106 - Thermal overload relay
ETIM 5
EC000106 - Thermal overload relay
ETIM 6
EC000106 - Thermal overload relay
ETIM 7
EC000106 - Thermal overload relay
GL Certificate
1SAA941007-0401/1SAA941001-0302
IDEA Granular Category Code (IGCC)
5364 >> Overload relay
Instructions and Manuals
2CDC106019M6802/2CDC106021M6801
LR Certificate
1SAA941001-0502
Maximum Operating Altitude Permissible
2000 m
Maximum Operating Voltage UL/CSA
Main Circuit 600 V AC
Minimum Order Quantity
1 piece
Number of Auxiliary Contacts NC
1
Number of Auxiliary Contacts NO
1
Number of Poles
3
Number of Protected Poles
3
Object Classification Code
F
Package Level 1 Depth / Length
82 mm
Package Level 1 EAN
4013614397950
Package Level 1 Gross Weight
0.116 kg
Package Level 1 Height
63 mm
Package Level 1 Units
1 piece
Package Level 1 Width
48 mm
Package Level 2 Depth / Length
395 mm
Package Level 2 EAN
4013614440663
Package Level 2 Gross Weight
8.738 kg
Package Level 2 Height
210 mm
Package Level 2 Units
40 piece
Package Level 2 Width
280 mm
Pollution Degree
3
Power Loss
at Rated Operating Conditions per Pole 1.1 W
Product Net Depth / Length
53.5 mm
Product Net Height
76.7 mm
Product Net Weight
0.104 kg
Product Net Width
45 mm
Rated Frequency (f)
Auxiliary Circuit 50 Hz/Auxiliary Circuit 60 Hz/Auxiliary Circuit DC/Main Circuit 50 Hz/Main Circuit 60 Hz
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 6 kV/Main Circuit 6 kV
Rated Insulation Voltage (Ui)
690 V
Rated Operational Current (Ie)
10 A
Rated Operational Current AC-15 (Ie)
(120 V) NC 3 A/(120 V) NO 0.5 A/(240 V) NC 3 A/(240 V) NO 0.5 A/(400 V) NC 0.75 A/(400 V) NO 0.5 A/(500 V) NC 0.75 A/(500 V) NO 0.5 A
Rated Operational Current AC-3 (Ie)
10 A
Rated Operational Current DC-13 (Ie)
(125 V) NC 0.55 A/(125 V) NO 0.55 A/(24 V) NC 1.25 A/(24 V) NO 1.25 A/(250 V) NC 0.27 A/(250 V) NO 0.27 A/(500 V) NC 0.15 A/(500 V) NO 0.15 A/(60 V) NC 0.55 A/(60 V) NO 0.55 A
Rated Operational Voltage
Auxiliary Circuit 600 V AC/DC/Main Circuit 690 V AC
Recommended Screw Driver
Main Circuit Pozidriv 2
Resistance to Shock acc. to IEC 60068-2-27
11 ms Pulse 22g
Resistance to Vibrations acc. to IEC 60068-2-6
3g / 3 ... 150 Hz
RINA Certificate
1SAA941000-0802
RMRS Certificate
1SAA941000-0704
RoHS Information
1SAD938507-0182
RoHS Status
Following EU Directive 2011/65/EU
Setting Range
7.6 ... 10 A
Standards
IEC/EN 60947-1/IEC/EN 60947-4-1/IEC/EN 60947-5-1/UL 60947-1/UL 60947-4-1
Suitable For
B6/BC6/B7/BC7/VB6/VBC6/VB7/VBC7/AS09/AS12/AS16
Tightening Torque
Auxiliary Circuit 1 ... 1.2 N·m/Main Circuit 1.1 ... 1.5 N·m
Tightening Torque UL/CSA
Auxiliary Circuit 9 ... 11 in·lb/Main Circuit 9 ... 13 in·lb
Time-Current Characteristic Curve
1SAZ700505F0016
UL Certificate
cUL_E48139/UL_E48139
UNSPSC
39121520
Wire Stripping Length
Auxiliary Circuit 9 mm/Main Circuit 12 mm
Reviews
0/ 5
average product rating
0
0
0
0
0
There are no reviews for this product. Be the first to leave your review.

No questions about this product, be the first and ask your question.

Application note

Brochure

CAD outline drawing

Catalogue

Certificate

Circuit diagram

Data sheet

Declaration of conformity

Drawing

Environmental product declaration

Information

Operating instruction

0.00грн.